# System Boot Progress on OpenBMC
|
||
|
|
|
||
|
|
Author: Andrew Geissler (geissonator)
|
||
|
|
|
||
|
|
Other contributors: None
|
||
|
|
|
||
|
|
Created: May 27, 2020
|
||
|
|
|
||
|
|
## Problem Description
|
||
|
|
|
||
|
|
The boot progress of an OpenBMC managed system is complex. There are a mix of
|
||
|
|
phosphor D-Bus properties, IPMI sensors, PLDM sensors, and Redfish properties to
|
||
|
|
represent it. The goal of this design document is to highlight these different
|
||
|
|
entities and provide a base for system implementors on what to implement.
|
||
|
|
|
||
|
|
## Background and References
|
||
|
|
|
||
|
|
[phosphor-state-manager][1] implements D-Bus properties which track the state of
|
||
|
|
the BMC, Chassis, and Host. This design is primarily focused on the status of
|
||
|
|
the Host since it is the most complex. Specifically the goal is to provide
|
||
|
|
detailed information on what the host is doing during a boot.
|
||
|
|
|
||
|
|
[HostState][2] provides basic `Off`/`Running` type information along with an
|
||
|
|
error state (`Quiesced`) and debug state (`DiagnosticMode`). The focus of this
|
||
|
|
document is the `Running` state. This simply indicates whether something is
|
||
|
|
running on the host processors.
|
||
|
|
|
||
|
|
phosphor-state-manager implements some other D-Bus properties that represent the
|
||
|
|
host boot progress:
|
||
|
|
|
||
|
|
- [xyz.openbmc_project.State.Boot.Progress][3]
|
||
|
|
- [xyz.openbmc_project.State.OperatingSystem.Status][4]
|
||
|
|
|
||
|
|
These two D-Bus properties are very IPMI-centric. They were defined based on two
|
||
|
|
IPMI sensors which are set by the host firmware as it boots the system.
|
||
|
|
|
||
|
|
PLDM also has a boot progress sensor. Search for "Boot Progress" in this
|
||
|
|
[doc][5]. A subset of this maps fairly well to the IPMI sensors above. This PLDM
|
||
|
|
sensor is not implemented yet in OpenBMC code.
|
||
|
|
|
||
|
|
Redfish represents system state in a variety of ways. The BMC, Chassis, and
|
||
|
|
System all implement a [Status][6] object. This provides a list of generic
|
||
|
|
`State` options which are applicable to Redfish objects. OpenBMC has the
|
||
|
|
following mapping for phosphor-state-manager to the Redfish System
|
||
|
|
[Status][state]:
|
||
|
|
|
||
|
|
- `xyz.openbmc_project.State.Host.HostState.Running` : `Enabled`
|
||
|
|
- `xyz.openbmc_project.State.Host.HostState.Quiesced` : `Quiesced`
|
||
|
|
- `xyz.openbmc_project.State.Host.HostState.DiagnosticMode` : `InTest`
|
||
|
|
|
||
|
|
As of [ComputerSystem.v1_13_0][7], the `BootProgress` object is officially in
|
||
|
|
the Redfish ComputerSystem schema.
|
||
|
|
|
||
|
|
To summarize, the `LastState` property under this new `BootProgress` object
|
||
|
|
tracks the following boot states of the system:
|
||
|
|
|
||
|
|
- None
|
||
|
|
- PrimaryProcessorInitializationStarted
|
||
|
|
- BusInitializationStarted
|
||
|
|
- MemoryInitializationStarted
|
||
|
|
- SecondaryProcessorInitializationStarted
|
||
|
|
- PCIResourceConfigStarted
|
||
|
|
- SystemHardwareInitializationComplete
|
||
|
|
- OSBootStarted
|
||
|
|
- OSRunning
|
||
|
|
- OEM
|
||
|
|
|
||
|
|
There is also a `LastStateTime` associated with this new BootProgress object
|
||
|
|
which should be updated with the date and time the `LastState` was last updated.
|
||
|
|
|
||
|
|
In the end, the goal is to be able to map either the IPMI or PLDM boot sensors
|
||
|
|
into all or some of the values in this new Redfish property.
|
||
|
|
|
||
|
|
Note that this design does not include multi-host computer system concepts but
|
||
|
|
it also does not preclude them. The `BootProgress` D-Bus property is associated
|
||
|
|
with a `/xyz/openbmc_project/state/host<X>` instance where <X> is the host
|
||
|
|
instance. Similarly, the Redfish system object is also an instance based object.
|
||
|
|
|
||
|
|
## Requirements
|
||
|
|
|
||
|
|
- Enhance the existing [BootProgress][3] D-Bus property to cover all supported
|
||
|
|
PLDM boot progress codes
|
||
|
|
- Create a new `BootProgressLastUpdate` D-Bus property that will hold the date
|
||
|
|
and time of the last update to `BootProgress`
|
||
|
|
- Ensure the `BootProgress` and `BootProgressLastUpdate` properties are updated
|
||
|
|
appropriately in both IPMI and PLDM based stacks
|
||
|
|
- It is the responsibility of the IPMI or PLDM implementation to update the
|
||
|
|
`BootProgress` property on D-Bus
|
||
|
|
- It is the responsibility the phosphor-state-manager to update the
|
||
|
|
`BootProgressLastUpdate` property on D-Bus when it sees `BootProgress`
|
||
|
|
updated
|
||
|
|
- Ensure the new Redfish `LastState` and `LastStateTime` properties have the
|
||
|
|
appropriate mappings to the `BootProgress` and `BootProgressLastUpdate D-Bus
|
||
|
|
properties
|
||
|
|
|
||
|
|
Different OpenBMC systems could support different boot progress codes, and
|
||
|
|
support them in different orders. This document does not try to set any
|
||
|
|
requirements on this other than that they must all be defined within the
|
||
|
|
`BootProgress` D-Bus property and the ones which have a mapping to the Redfish
|
||
|
|
BootProgress object will be shown via the Redfish interface.
|
||
|
|
|
||
|
|
## Proposed Design
|
||
|
|
|
||
|
|
[BootProgress][3] will be enhanced to support a superset of what is provided by
|
||
|
|
IPMI and PLDM.
|
||
|
|
|
||
|
|
IPMI code already sets the `BootProgress` D-Bus property based on a config file.
|
||
|
|
Look for `fw_boot_sensor` in this [file][8] for an example of how a particular
|
||
|
|
IPMI sensor is mapped to this D-Bus property.
|
||
|
|
|
||
|
|
PLDM software will do something similar.
|
||
|
|
|
||
|
|
bmcweb will then use this `BootProgress` D-Bus interface to respond
|
||
|
|
appropriately to Redfish requests.
|
||
|
|
|
||
|
|
## Alternatives Considered
|
||
|
|
|
||
|
|
A lot of system BIOS's provided some form of a detailed boot progress codes.
|
||
|
|
UEFI has POST codes, POWER has istep progress codes. If more fine grained
|
||
|
|
details were needed, we could look into using these. Currently though the need
|
||
|
|
is just high level boot progress. Note that these POST/istep codes could be
|
||
|
|
mapped to the appropriate BootProgress value if desired (or for cases where the
|
||
|
|
host does not support an IPMI or PLDM stack that has BootProgress in it).
|
||
|
|
|
||
|
|
## Impacts
|
||
|
|
|
||
|
|
Each system will need to document which `BootProgress` codes they support and
|
||
|
|
the expected order of them when a system is booting.
|
||
|
|
|
||
|
|
## Testing
|
||
|
|
|
||
|
|
Ensure an IPMI and PLDM based system boot and update the `BootProgress` D-Bus
|
||
|
|
property as expected.
|
||
|
|
|
||
|
|
[1]:
|
||
|
|
https://github.com/openbmc/phosphor-state-manager#state-tracking-and-control
|
||
|
|
[2]:
|
||
|
|
https://github.com/openbmc/phosphor-dbus-interfaces/blob/master/yaml/xyz/openbmc_project/State/Host.interface.yaml
|
||
|
|
[3]:
|
||
|
|
https://github.com/openbmc/phosphor-dbus-interfaces/blob/master/yaml/xyz/openbmc_project/State/Boot/Progress.interface.yaml
|
||
|
|
[4]:
|
||
|
|
https://github.com/openbmc/phosphor-dbus-interfaces/blob/master/yaml/xyz/openbmc_project/State/OperatingSystem/Status.interface.yaml
|
||
|
|
[5]:
|
||
|
|
https://www.dmtf.org/sites/default/files/standards/documents/DSP0249_1.0.0.pdf
|
||
|
|
[6]: http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/Status
|
||
|
|
[7]: https://redfish.dmtf.org/schemas/v1/ComputerSystem.v1_13_0.json
|
||
|
|
[8]:
|
||
|
|
https://github.com/openbmc/meta-ibm/blob/master/recipes-phosphor/configuration/acx22-yaml-config/acx22-ipmi-sensors-mrw.yaml
|