# Monitoring and Logging OpenBMC Systemd Target and Service Failures
|
||
|
|
|
||
|
|
Author: Andrew Geissler < geissonator >
|
||
|
|
|
||
|
|
Created: June 18, 2019 Last Updated: Feb 21, 2022
|
||
|
|
|
||
|
|
## Problem Description
|
||
|
|
|
||
|
|
OpenBMC uses systemd to coordinate the starting and stopping of its
|
||
|
|
applications. For example, systemd is used to start all of OpenBMC's initial
|
||
|
|
services, to power on and off the servers it manages, and to perform operations
|
||
|
|
like firmware updates.
|
||
|
|
|
||
|
|
[openbmc-systemd.md][1] has a good summary of systemd and the basics of how it
|
||
|
|
is used within OpenBMC.
|
||
|
|
|
||
|
|
At a high level, systemd is composed of units. For OpenBMC, the two key unit
|
||
|
|
types are target and service.
|
||
|
|
|
||
|
|
There are situations where OpenBMC systemd targets fail. They fail due to a
|
||
|
|
target or service within them hitting some sort of error condition. In some
|
||
|
|
cases, the unit which caused the failure will log an error to phosphor-logging
|
||
|
|
but in some situations (segfault, unhandled exception, unhandled error path,
|
||
|
|
...), there will be no indication to the end user that something failed. It is
|
||
|
|
critical that if a systemd target fails within OpenBMC, the user be notified.
|
||
|
|
|
||
|
|
There are also scenarios where a system has successfully started all targets but
|
||
|
|
a running service within that target fails. Some services are not all that
|
||
|
|
critical, but something like fan-control or a power monitoring service, could be
|
||
|
|
very critical. At a minimum, need to ensure the user of the system is informed
|
||
|
|
that a critical service has failed. The solution proposed in this document does
|
||
|
|
not preclude service owners from doing other recovery, this solution just
|
||
|
|
ensures a bare minimum of reporting is done when a failure occurs.
|
||
|
|
|
||
|
|
## Background and References
|
||
|
|
|
||
|
|
See the [phosphor-state-manager][2] repository for background information on
|
||
|
|
state management and systemd within OpenBMC.
|
||
|
|
|
||
|
|
systemd provides signals when units complete and provides status on that
|
||
|
|
completed unit. See the JobNew()/JobRemoved() section in the [systemd dbus
|
||
|
|
API][3]. The six different results are:
|
||
|
|
|
||
|
|
```
|
||
|
|
done, canceled, timeout, failed, dependency, skipped
|
||
|
|
```
|
||
|
|
|
||
|
|
phosphor-state-manager code already monitors for these signals but only looks
|
||
|
|
for a status of `done` to know when to mark the corresponding dbus object as
|
||
|
|
ready(bmc)/on(chassis)/running(host).
|
||
|
|
|
||
|
|
The proposal within this document is to monitor for these other results and log
|
||
|
|
an appropriate error to phosphor-logging.
|
||
|
|
|
||
|
|
A systemd unit that is a service will only enter into a `failed` state after all
|
||
|
|
systemd defined retries have been executed. For OpenBMC systems, that involves 2
|
||
|
|
restarts within a 30 second window.
|
||
|
|
|
||
|
|
## Requirements
|
||
|
|
|
||
|
|
### Systemd Target Units
|
||
|
|
|
||
|
|
- Must be able to monitor any arbitrary systemd target and log a defined error
|
||
|
|
based on the type of failure the target encountered
|
||
|
|
- Must be configurable
|
||
|
|
- Target: Choose any systemd target
|
||
|
|
- Status: Choose one or more status's to monitor for
|
||
|
|
- Error to log: Specify error to log when error is detected
|
||
|
|
- Must be able to take multiple configure files as input on startup
|
||
|
|
- Support a `default` for errors to monitor for
|
||
|
|
- This will be `timeout`,`failed`, and `dependency`
|
||
|
|
- Error will always be the configured one with additional data indicating the
|
||
|
|
status that failed (i.e. canceled, timeout, ...)
|
||
|
|
- Example:
|
||
|
|
|
||
|
|
```
|
||
|
|
xyz.openbmc_project.State.BMC.Error.MultiUserTargetFailure
|
||
|
|
STATUS=timeout
|
||
|
|
```
|
||
|
|
|
||
|
|
- By default, enable this monitor and logging service for all critical OpenBMC
|
||
|
|
targets
|
||
|
|
- Critical systemd targets are ones used by phosphor-state-manager
|
||
|
|
- BMC: multi-user.target
|
||
|
|
- Chassis: obmc-chassis-poweron@0.target, obmc-chassis-poweroff@0.target
|
||
|
|
- Host: obmc-host-start@0.target, obmc-host-startmin@0.target,
|
||
|
|
obmc-host-shutdown@0.target, obmc-host-stop@0.target,
|
||
|
|
obmc-host-reboot@0.target
|
||
|
|
- The errors for these must be defined in phosphor-dbus-interfaces
|
||
|
|
- Limitations:
|
||
|
|
- Fully qualified target name must be input (i.e. no templated / wild card
|
||
|
|
target support)
|
||
|
|
|
||
|
|
### Systemd Service Units
|
||
|
|
|
||
|
|
- Must be able to monitor any arbitrary systemd service within OpenBMC
|
||
|
|
- Service(s) to monitor must be configurable
|
||
|
|
- Log an error indicating a service has failed (with service name in log)
|
||
|
|
- `xyz.openbmc_project.State.Error.CriticalServiceFailure`
|
||
|
|
- Collect a BMC dump
|
||
|
|
- Changes BMC state (CurrentBMCState) to indicate a degraded mode of the BMC
|
||
|
|
- Report changed state externally via Redfish managers/bmc state
|
||
|
|
|
||
|
|
## Proposed Design
|
||
|
|
|
||
|
|
Create a new standalone application in phosphor-state-manager which will load
|
||
|
|
json file(s) on startup.
|
||
|
|
|
||
|
|
The json file(s) would have the following format for targets:
|
||
|
|
|
||
|
|
```
|
||
|
|
{
|
||
|
|
"targets" : [
|
||
|
|
{
|
||
|
|
"name": "multi-user.target",
|
||
|
|
"errorsToMonitor": ["default"],
|
||
|
|
"errorToLog": "xyz.openbmc_project.State.BMC.Error.MultiUserTargetFailure",
|
||
|
|
},
|
||
|
|
{
|
||
|
|
"name": "obmc-chassis-poweron@0.target",
|
||
|
|
"errorsToMonitor": ["timeout", "failed"],
|
||
|
|
"errorToLog": "xyz.openbmc_project.State.Chassis.Error.PowerOnTargetFailure",
|
||
|
|
}
|
||
|
|
]
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
The json (files) would have the following format for services:
|
||
|
|
|
||
|
|
```
|
||
|
|
{
|
||
|
|
"services" : [
|
||
|
|
"xyz.openbmc_project.biosconfig_manager.service",
|
||
|
|
"xyz.openbmc_project.Dump.Manager.service"
|
||
|
|
]
|
||
|
|
}
|
||
|
|
```
|
||
|
|
|
||
|
|
On startup, all input json files will be loaded and monitoring will be setup.
|
||
|
|
|
||
|
|
This application will not register any interfaces on D-Bus but will subscribe to
|
||
|
|
systemd dbus signals for JobRemoved. sdeventplus will be used for all D-Bus
|
||
|
|
communication.
|
||
|
|
|
||
|
|
For additional debug, the errors may be registered with the BMC Dump function to
|
||
|
|
ensure the cause of the failure can be determined. This requires the errors
|
||
|
|
logged by this service be put into `phosphor-debug-errors/errors_watch.yaml`.
|
||
|
|
|
||
|
|
For service failures, a dump will be collected by default because the BMC will
|
||
|
|
be moved into a Quisced state.
|
||
|
|
|
||
|
|
Note that services which are short running applications responsible for
|
||
|
|
transitioning the system from one target to another (i.e. chassis power on/off,
|
||
|
|
starting/stopping the host, ...) are critical services, but they are not the
|
||
|
|
type of services to be monitored. Their failures will cause systemd targets to
|
||
|
|
fail which will fall into the target monitoring piece of this design. The
|
||
|
|
service monitoring is meant for long running services which stay running after a
|
||
|
|
target has completed.
|
||
|
|
|
||
|
|
## Alternatives Considered
|
||
|
|
|
||
|
|
Units have an OnError directive. Could put the error logging logic within that
|
||
|
|
path but it introduces more complexity to OpenBMC systemd usage which is already
|
||
|
|
quite complicated.
|
||
|
|
|
||
|
|
Could implement this within the existing state manager applications since they
|
||
|
|
are already monitoring some of these units. The standalone application and
|
||
|
|
generic capability to monitor any unit was chosen as a better option.
|
||
|
|
|
||
|
|
## Impacts
|
||
|
|
|
||
|
|
A phosphor-logging event will be logged when one of the units listed above
|
||
|
|
fails. This will be viewable by owners of the system. There may be situations
|
||
|
|
where two logs are generated for the same issue. For example, if the power
|
||
|
|
application detects an issue during power on and logs it to phosphor-logging and
|
||
|
|
then returns non zero to systemd, the target that service is a part of will also
|
||
|
|
fail and the code logic defined in this design will also log an error.
|
||
|
|
|
||
|
|
The thought is that two errors are better than none. Also, there is a plugin
|
||
|
|
architecture being defined for phosphor-logging. The user could monitor for that
|
||
|
|
first error within the phosphor-logging plugin architecture and as a defined
|
||
|
|
action, cancel the systemd target. A target status of `canceled` will not result
|
||
|
|
in phosphor-state-manager generating an error.
|
||
|
|
|
||
|
|
## Testing
|
||
|
|
|
||
|
|
Need to cause all units mentioned within this design to fail. They should fail
|
||
|
|
for each of the reasons defined within this design and the error generated for
|
||
|
|
each scenario should be verified.
|
||
|
|
|
||
|
|
[1]: https://github.com/openbmc/docs/blob/master/architecture/openbmc-systemd.md
|
||
|
|
[2]: https://github.com/openbmc/phosphor-state-manager
|
||
|
|
[3]: https://www.freedesktop.org/wiki/Software/systemd/dbus/
|