This document is intended to provide a set of ipmitool commands for OpenBMC usage.
Power
1. View server status
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power status
2. Server power on
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power on
3. Server power off
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power off
4. Server power reset
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power reset
5. Server power cycle
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power cycle
6. Server power soft
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power soft
7. Send a diagnostic interrupt directly to the processor(not support)
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power diag
Users
1. View information for all users
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user list
2. Display a brief summary of BMC users
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user summary
3. Create a BMC user with a given name
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user set name <userid> <username>
4. Set a given user with a given password
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user set password <userid>[<password>]
5. Disable designated users from accessing BMC
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user disable <userid>
6. Enable the specified user to access BMC
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user enable <userid>
Field-replaceable Unit (FRU)
1. View FRU information
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" fru list
Sensor Data Record (SDR)
1. View SDR information
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sdr
2. Query related SDR information in BMC
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sdr info
3. View sensor date records
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sdr list [all|full|compact|event|mcloc|fru|generic]
##
all : All SDR records (sensors and positioners)
full : Complete sensor recording
compact : Simple sensor recording
event : Event information recorded by the sensor
mcloc : Manage controller locator records
fru : FRU (Field Replaceable Unit) locator record
generic : General SDR records
Sensors
1. View sensor information
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sensor list
Management Controller (MC)
1. Instruct the BMC to perform a cold reset
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" mc reset cold
2. Instruct the BMC to perform a warm reset(not supported)
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" mc reset warm
3. View BMC information
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" mc info
4. View the currently available operation options of BMC
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" mc getenables
Channels
1. Display the authentication function about the selected information
channel
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" channel authcap <channel number> <max privilege>
2. Display the information for the selected channel
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" channel info [<channel number>]
3. View channel information
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" channel info
Chassis
1. Display information about the high-level status of the system rack and
power subsystem.
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis status
2. The command will return the power on time
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis poh
3. Query the reason for the last system restart.(not supported)
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis restart_cause
4. Set rack power strategy in case of power failure
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis policy <state>
##
list : return supported policies
always-on : turn on when power is restored
previous : return to previous state when power is restored
always-off : stay off after power is restored
5. View and change power status
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis power
##
status : show current status
on : power on
off : power off
reset : power reset
soft : power soft
cycle : power cycle
6. Set boot device for next system restart
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootdev <device>
Currently supported devices:
| device | function |
|---|---|
| none | do not change boot device |
| pxe | boot from pxe |
| disk | boot from BIOS default boot device |
| safe | boot from BIOS default boot device,but requires a safe mode |
| diag | boot from the diagnostic partition |
| cdrom | boot from the CD/DVD |
| bios | enter bios settings |
If you want to make your override persistent over reboots use the persistent
option:
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootdev <device> options=persistent
If the main host machine is based on the x86 CPU you need also pay attention to
the legacy/EFI mode selector. By default IPMI overrides boot source with the
legacy mode enabled. To set EFI mode use efiboot option:
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootdev <device> options=efiboot
You can combine options with a help of ,:
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootdev <device> options=persistent,efiboot
To read current boot source override setting:
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootparam get 5
7. Control panel logo light
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis identify <interval>
Local Area Network(LAN)
1. Output the current configuration information of a given channel
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" lan print [<channel number>]
2. Set the given parameters for the given channel
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" lan set <channel> <command> <parameter>
##
Valid parameter
ipaddr <x.x.x.x> : Set ip for this channel
netmask <x.x.x.x> : Set netmask for this channel
macaddr<xx:xx:xx:xx:xx:xx> : Set the mac address for this channel
defgw ipaddr <x.x.x.x> : Set the default gateway IP address
defgw macaddr<xx:xx:xx:xx:xx:xx> : Set the mac address of the default gateway
bakgw ipaddr <x.x.x.x> : Set the IP address of the backup gateway
bakgw macaddr<xx:xx:xx:xx:xx:xx> : Set the IP address of the backup gateway
password <pass> : Set no user password
access <on|off> : Set the LAN channel access mode
System Event Log (SEL)
1. Query the relevant information about SEL and its content in BMC
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sel info
2. Clear the information in SEL,but it cannot be undone.
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sel clear
3. Delete a single event
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sel delete <number>
4. Display the current time of the SEL clock
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sel time get
Session
1. Display session information
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" session info all
Serial Over Lan (SOL)
1. Retrieve Serial-Over-LAN configuration information for the specified
channel.
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sol info [<channel number>]
2. Put ipmitool into Serial Over LAN mode
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sol activate
3. Disable serial LAN in BMC mode
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sol deactivate