# System Power Mode and Idle Power Saver Support
|
|
|
|
Author: Chris Cain
|
|
|
|
Other contributors: Martha Broyles
|
|
|
|
Created: 12/03/2020
|
|
|
|
## Problem Description
|
|
|
|
Power management on POWER platforms needs assistance from the BMC for managing
|
|
the system power mode and idle power save modes. We need the ability to set and
|
|
query the system power mode and also the ability to control and set idle power
|
|
save parameters. This design is only applicable to POWER processors.
|
|
|
|
## Background and References
|
|
|
|
Each POWER processor contains an embedded PowerPC 405 processor that is referred
|
|
to as the On Chip Controller or OCC. The OCC provides real time power and
|
|
thermal monitoring and control. When a system is powered on, the OCCs will go to
|
|
an Active state. Anytime the OCC state changes to active, the BMC will need to
|
|
send a mode change and idle power saver (IPS) settings to the OCC. It will also
|
|
need to send the commands if the user changes the mode or idle power save
|
|
parameters.
|
|
|
|
## Requirements
|
|
|
|
When a system is booted, the OCC will move to an ACTIVE state. In the ACTIVE
|
|
state, the OCC is managing the processor frequency, power consumption, and
|
|
monitoring the systems thermal sensors. For certain error conditions it may be
|
|
necessary to reset the OCC. When this happens, the OCC will move out of ACTIVE
|
|
state. After recovery, the OCC will be put back into the ACTIVE state. Anytime
|
|
the OCC state changes to ACTIVE or the customer updates these new parameters at
|
|
runtime, the BMC will need to send the mode and the idle power saver settings to
|
|
the OCC.
|
|
|
|
PowerMode was added to version 2021.1 Redfish Schema Supplement:
|
|
https://www.dmtf.org/sites/default/files/standards/documents/DSP0268_2021.1.pdf
|
|
|
|
Current Customer Settable System Power Modes that will be sent to the OCCs:
|
|
|
|
- Static
|
|
- Power Saver
|
|
- Maximum Performance
|
|
|
|
A proposal for adding Idle Power Saving parameters was submitted to the Redfish
|
|
committee and will be used if/when approved.
|
|
|
|
Customer Settable Idle Power Save Parameters:
|
|
|
|
- Enabled / Disabled
|
|
- Enter Delay Time (in seconds)
|
|
- Enter Utilization threshold (percentage)
|
|
- Exit Delay Time (in seconds)
|
|
- Exit Utilization threshold (percentage)
|
|
|
|
Defaults will need to be configurable by the system owner (via JSON file)
|
|
|
|
## Proposed Design
|
|
|
|
The new code would be part of the openpower-occ-control repository. New code
|
|
will be triggered by the following:
|
|
|
|
- OCC poll response data showing a new state of Active (0x03)
|
|
- OCC Active sensor is enabled (may be covered in above bullet)
|
|
- Customer updates system power mode user interface or Redfish interface
|
|
- Customer updates idle power save setting or Redfish interface
|
|
|
|
Code will need to trigger off of OCC state changes. The kernel currently sends a
|
|
POLL command to the OCC periodically (every second). The OCC state is available
|
|
in the OCC poll response data.
|
|
|
|
When initiated, the new code will send a SET_MODE_AND_STATE command (0x20) to
|
|
the OCC and a SET_CONFIG_DATA (0x21) command with the Idle Power Saver
|
|
parameters. These commands are defined in the OCC Interface Spec:
|
|
https://github.com/open-power/docs/blob/master/occ/OCC_P9_FW_Interfaces.pdf
|
|
|
|
Default values will also be defined for Power Mode and Idle Power Saver
|
|
parameters for the system. If the customer has not yet set any of these
|
|
parameters, these default values will be used. If/when the customer does set any
|
|
of these, that new customer parameter will become current and the default value
|
|
will no longer be used.
|
|
|
|
The customer requested PowerMode and Idle Power Saver parameters will be stored
|
|
as D-Bus object in the phosphor-dbus-interfaces repository:
|
|
xyz/openbmc_project/Control/Power/Mode.interface.yaml Once set, these values
|
|
will be retained across power cycles, AC loss, code updates, etc.
|
|
|
|
## Alternatives Considered
|
|
|
|
- Using hardcoded power mode and Idle Power Save parameters (no flexibility to
|
|
control system power usage)
|
|
|
|
## Impacts
|
|
|
|
New interfaces that were described in the requirements section will be
|
|
implemented. Parameters should be able to be set via user interface or via
|
|
Redfish. API impact - Add Redfish support for new parameters as well as new user
|
|
interface to allow customer to set power mode and idle power saver settings
|
|
Security impact - update of these parameters should be able to be restricted to
|
|
specific users/groups (may not want any user updating these parameters)
|
|
Documentation impact - need to document new parameters Performance impact -
|
|
minimal, new code will only execute on OCC state change which should normally
|
|
happen once at boot time or when user changes parameters. The new code is only
|
|
sending 2 additional commands which should complete within a few seconds.
|
|
Developer impact - code to be written by OCC team with guidance from OpenBMC
|
|
power management team Upgradability impact - None
|
|
|
|
## Testing
|
|
|
|
This will be able to be tested by directly updating the power mode and idle
|
|
power saver setting. This testing will be automated
|