# PLDM stack on OpenBMC
|
|
|
|
Author: Deepak Kodihalli <dkodihal@linux.vnet.ibm.com> <dkodihal>
|
|
|
|
Created: 2019-01-22
|
|
|
|
## Problem Description
|
|
|
|
On OpenBMC, in-band IPMI is currently the primary industry-standard means of
|
|
communication between the BMC and the Host firmware. We've started hitting some
|
|
inherent limitations of IPMI on OpenPOWER servers: a limited number of sensors,
|
|
and a lack of a generic control mechanism (sensors are a generic monitoring
|
|
mechanism) are the major ones. There is a need to improve upon the communication
|
|
protocol, but at the same time inventing a custom protocol is undesirable.
|
|
|
|
This design aims to employ Platform Level Data Model (PLDM), a standard
|
|
application layer communication protocol defined by the DMTF. PLDM draws inputs
|
|
from IPMI, but it overcomes most of the latter's limitations. PLDM is also
|
|
designed to run on standard transport protocols, for e.g. MCTP (also designed by
|
|
the DMTF). MCTP provides for a common transport layer over several physical
|
|
channels, by defining hardware bindings. The solution of PLDM over MCTP also
|
|
helps overcome some of the limitations of the hardware channels that IPMI uses.
|
|
|
|
PLDM's purpose is to enable all sorts of "inside the box communication": BMC -
|
|
Host, BMC - BMC, BMC - Network Controller and BMC - Other (for e.g. sensor)
|
|
devices.
|
|
|
|
## Background and References
|
|
|
|
PLDM is designed to be an effective interface and data model that provides
|
|
efficient access to low-level platform inventory, monitoring, control, event,
|
|
and data/parameters transfer functions. For example, temperature, voltage, or
|
|
fan sensors can have a PLDM representation that can be used to monitor and
|
|
control the platform using a set of PLDM messages. PLDM defines data
|
|
representations and commands that abstract the platform management hardware.
|
|
|
|
PLDM groups commands under broader functions, and defines separate
|
|
specifications for each of these functions (also called PLDM "Types"). The
|
|
currently defined Types (and corresponding specs) are : PLDM base (with
|
|
associated IDs and states specs), BIOS, FRU, Platform monitoring and control,
|
|
Firmware Update and SMBIOS. All these specifications are available at:
|
|
|
|
https://www.dmtf.org/standards/pmci
|
|
|
|
Some of the reasons PLDM sounds promising (some of these are advantages over
|
|
IPMI):
|
|
|
|
- Common in-band communication protocol.
|
|
|
|
- Already existing PLDM Type specifications that cover the most common
|
|
communication requirements. Up to 64 PLDM Types can be defined (the last one
|
|
is OEM). At the moment, 6 are defined. Each PLDM type can house up to 256 PLDM
|
|
commands.
|
|
|
|
- PLDM sensors are 2 bytes in length.
|
|
|
|
- PLDM introduces the concept of effecters - a control mechanism. Both sensors
|
|
and effecters are associated to entities (similar to IPMI, entities can be
|
|
physical or logical), where sensors are a mechanism for monitoring and
|
|
effecters are a mechanism for control. Effecters can be numeric or state
|
|
based. PLDM defines commonly used entities and their IDs, but there 8K slots
|
|
available to define OEM entities.
|
|
|
|
- A very active PLDM related working group in the DMTF.
|
|
|
|
The plan is to run PLDM over MCTP. MCTP is defined in a spec of its own, and a
|
|
proposal on the MCTP design is in discussion already. There's going to be an
|
|
intermediate PLDM over MCTP binding layer, which lets us send PLDM messages over
|
|
MCTP. This is defined in a spec of its own, and the design for this binding will
|
|
be proposed separately.
|
|
|
|
## Requirements
|
|
|
|
How different BMC applications make use of PLDM messages is outside the scope of
|
|
this requirements doc. The requirements listed here are related to the PLDM
|
|
protocol stack and the request/response model:
|
|
|
|
- Marshalling and unmarshalling of PLDM messages, defined in various PLDM Type
|
|
specs, must be implemented. This can of course be staged based on the need of
|
|
specific Types and functions. Since this is just encoding and decoding PLDM
|
|
messages, this can be a library that could shared between the BMC, and other
|
|
firmware stacks. The specifics of each PLDM Type (such as FRU table
|
|
structures, sensor PDR structures, etc) are implemented by this lib.
|
|
|
|
- Mapping PLDM concepts to native OpenBMC concepts must be implemented. For
|
|
e.g.: mapping PLDM sensors to phosphor-hwmon hosted D-Bus objects, mapping
|
|
PLDM FRU data to D-Bus objects hosted by phosphor-inventory-manager, etc. The
|
|
mapping shouldn't be restrictive to D-Bus alone (meaning it shouldn't be
|
|
necessary to put objects on the Bus just to serve PLDM requests, a problem
|
|
that exists with phosphor-host-ipmid today). Essentially these are platform
|
|
specific PLDM message handlers.
|
|
|
|
- The BMC should be able to act as a PLDM responder as well as a PLDM requester.
|
|
As a PLDM requester, the BMC can monitor/control other devices. As a PLDM
|
|
responder, the BMC can react to PLDM messages directed to it via requesters in
|
|
the platform.
|
|
|
|
- As a PLDM requester, the BMC must be able to discover other PLDM enabled
|
|
components in the platform.
|
|
|
|
- As a PLDM requester, the BMC must be able to send simultaneous messages to
|
|
different responders.
|
|
|
|
- As a PLDM requester, the BMC must be able to handle out of order responses.
|
|
|
|
- As a PLDM responder, the BMC may simultaneously respond to messages from
|
|
different requesters, but the spec doesn't mandate this. In other words the
|
|
responder could be single-threaded.
|
|
|
|
- It should be possible to plug-in OEM PLDM types/functions into the PLDM stack.
|
|
|
|
## Proposed Design
|
|
|
|
This document covers the architectural, interface, and design details. It
|
|
provides recommendations for implementations, but implementation details are
|
|
outside the scope of this document.
|
|
|
|
The design aims at having a single PLDM daemon serve both the requester and
|
|
responder functions, and having transport specific endpoints to communicate on
|
|
different channels.
|
|
|
|
The design enables concurrency aspects of the requester and responder functions,
|
|
but the goal is to employ asynchronous IO and event loops, instead of multiple
|
|
threads, wherever possible.
|
|
|
|
The following are high level structural elements of the design:
|
|
|
|
### PLDM encode/decode libraries
|
|
|
|
This library would take a PLDM message, decode it and extract the different
|
|
fields of the message. Conversely, given a PLDM Type, command code, and the
|
|
command's data fields, it would make a PLDM message. The thought is to design
|
|
this as a common library, that can be used by the BMC and other firmware stacks,
|
|
because it's the encode/decode and protocol piece (and not the handling of a
|
|
message).
|
|
|
|
### PLDM provider libraries
|
|
|
|
These libraries would implement the platform specific handling of incoming PLDM
|
|
requests (basically helping with the PLDM responder implementation, see next
|
|
bullet point), so for instance they would query D-Bus objects (or even something
|
|
like a JSON file) to fetch platform specific information to respond to the PLDM
|
|
message. They would link with the encode/decode lib.
|
|
|
|
It should be possible to plug-in a provider library, that lets someone add
|
|
functionality for new PLDM (standard as well as OEM) Types. The libraries would
|
|
implement a "register" API to plug-in handlers for specific PLDM messages.
|
|
Something like:
|
|
|
|
template <typename Handler, typename... args> auto register(uint8_t type,
|
|
uint8_t command, Handler handler);
|
|
|
|
This allows for providing a strongly-typed C++ handler registration scheme. It
|
|
would also be possible to validate the parameters passed to the handler at
|
|
compile time.
|
|
|
|
### Request/Response Model
|
|
|
|
The PLDM daemon links with the encode/decode and provider libs. The daemon would
|
|
have to implement the following functions:
|
|
|
|
#### Receiver/Responder
|
|
|
|
The receiver wakes up on getting notified of incoming PLDM messages (via D-Bus
|
|
signal or callback from the transport layer) from a remote PLDM device. If the
|
|
message type is "Request" it would route them to a PLDM provider library. Via
|
|
the library, asynchronous D-Bus calls (using sdbusplus-asio) would be made, so
|
|
that the receiver can register a handler for the D-Bus response, instead of
|
|
having to wait for the D-Bus response. This way it can go back to listening for
|
|
incoming PLDM messages.
|
|
|
|
In the D-Bus response handler, the receiver will send out the PLDM response
|
|
message via the transport's send message API. If the transport's send message
|
|
API blocks for a considerably long duration, then it would have to be run in a
|
|
thread of it's own.
|
|
|
|
If the incoming PLDM message is of type "Response", then the receiver emits a
|
|
D-Bus signal pointing to the response message. Any time the message is too large
|
|
to fit in a D-Bus payload, the message is written to a file, and a read-only
|
|
file descriptor pointing to that file is contained in the D-Bus signal.
|
|
|
|
#### Requester
|
|
|
|
Designing the BMC as a PLDM requester is interesting. We haven't had this with
|
|
IPMI, because the BMC was typically an IPMI server. PLDM requester functions
|
|
will be spread across multiple OpenBMC applications (instead of a single big
|
|
requester app) - based on the responder they're talking to and the high level
|
|
function they implement. For example, there could be an app that lets the BMC
|
|
upgrade firmware for other devices using PLDM - this would be a generic app in
|
|
the sense that the same set of commands might have to be run irrespective of the
|
|
device on the other side. There could also be an app that does fan control on a
|
|
remote device, based on sensors from that device and algorithms specific to that
|
|
device.
|
|
|
|
##### Proposed requester design
|
|
|
|
A requester app/flow comprises of the following :
|
|
|
|
- Linkage with a PLDM encode/decode library, to be able to pack PLDM requests
|
|
and unpack PLDM responses.
|
|
|
|
- A D-Bus API to generate a unique PLDM instance id. The id needs to be unique
|
|
across all outgoing PLDM messages (from potentially different processes). This
|
|
needs to be on D-Bus because the id needs to be unique across PLDM requester
|
|
app processes.
|
|
|
|
- A requester client API that provides blocking and non-blocking functions to
|
|
transfer a PLDM request message and to receive the corresponding response
|
|
message, over MCTP (the blocking send() will return a PLDM response). This
|
|
will be a thin wrapper over the socket API provided by the mctp demux daemon.
|
|
This will provide APIs for common tasks so that the same may not be
|
|
re-implemented in each PLDM requester app. This set of API will be built into
|
|
the encode/decode library (so libpldm would house encode/decode APIs, and
|
|
based on a compile time flag, the requester APIs as well). A PLDM requester
|
|
app can choose to not use the client requester APIs, and instead can directly
|
|
talk to the MCTP demux daemon.
|
|
|
|
##### Proposed requester design - flow diagrams
|
|
|
|
a) With blocking API
|
|
|
|
```
|
|
+---------------+ +----------------+ +----------------+ +-----------------+
|
|
|BMC requester/ | |PLDM requester | |PLDM responder | |PLDM Daemon |
|
|
|client app | |lib (part of | | | | |
|
|
| | |libpldm) | | | | |
|
|
+-------+-------+ +-------+--------+ +--------+-------+ +---------+-------+
|
|
| | | |
|
|
|App starts | | |
|
|
| | | |
|
|
+------------------------------->setup connection with | |
|
|
|init(non_block=false) |MCTP daemon | |
|
|
| | | |
|
|
+<-------+return_code+----------+ | |
|
|
| | | |
|
|
| | | |
|
|
| | | |
|
|
+------------------------------>+ | |
|
|
|encode_pldm_cmd(cmd code, args)| | |
|
|
| | | |
|
|
+<----+returns pldm_msg+--------+ | |
|
|
| | | |
|
|
| | | |
|
|
|----------------------------------------------------------------------------------------------->|
|
|
|DBus.getPLDMInstanceId() | | |
|
|
| | | |
|
|
|<-------------------------returns PLDM instance id----------------------------------------------|
|
|
| | | |
|
|
+------------------------------>+ | |
|
|
|send_msg(mctp_eids, pldm_msg) +----------------------------->+ |
|
|
| |write msg to MCTP socket | |
|
|
| +----------------------------->+ |
|
|
| |call blocking recv() on socket| |
|
|
| | | |
|
|
| +<-+returns pldm_response+-----+ |
|
|
| | | |
|
|
| +----+ | |
|
|
| | | verify eids, instance id| |
|
|
| +<---+ | |
|
|
| | | |
|
|
+<--+returns pldm_response+-----+ | |
|
|
| | | |
|
|
| | | |
|
|
| | | |
|
|
+------------------------------>+ | |
|
|
|decode_pldm_cmd(pldm_resp, | | |
|
|
| output args) | | |
|
|
| | | |
|
|
+------------------------------>+ | |
|
|
|close_connection() | | |
|
|
+ + + +
|
|
```
|
|
|
|
b) With non-blocking API
|
|
|
|
```
|
|
+---------------+ +----------------+ +----------------+ +---------------+
|
|
|BMC requester/ | |PLDM requester | |PLDM responder | |PLDM daemon |
|
|
|client app | |lib (part of | | | | |
|
|
| | |libpldm) | | | | |
|
|
+-------+-------+ +-------+--------+ +--------+-------+ +--------+------+
|
|
| | | |
|
|
|App starts | | |
|
|
| | | |
|
|
+------------------------------->setup connection with | |
|
|
|init(non_block=true |MCTP daemon | |
|
|
| int* o_mctp_fd) | | |
|
|
| | | |
|
|
+<-------+return_code+----------+ | |
|
|
| | | |
|
|
| | | |
|
|
| | | |
|
|
+------------------------------>+ | |
|
|
|encode_pldm_cmd(cmd code, args)| | |
|
|
| | | |
|
|
+<----+returns pldm_msg+--------+ | |
|
|
| | | |
|
|
|-------------------------------------------------------------------------------------------->|
|
|
|DBus.getPLDMInstanceId() | | |
|
|
| | | |
|
|
|<-------------------------returns PLDM instance id-------------------------------------------|
|
|
| | | |
|
|
| | | |
|
|
+------------------------------>+ | |
|
|
|send_msg(eids, pldm_msg, +----------------------------->+ |
|
|
| non_block=true) |write msg to MCTP socket | |
|
|
| +<---+return_code+-------------+ |
|
|
+<-+returns rc, doesn't block+--+ | |
|
|
| | | |
|
|
+------+ | | |
|
|
| |Add EPOLLIN on mctp_fd | | |
|
|
| |to self.event_loop | | |
|
|
+<-----+ | | |
|
|
| + | |
|
|
+<----------------------+PLDM response msg written to mctp_fd+-+ |
|
|
| + | |
|
|
+------+EPOLLIN on mctp_fd | | |
|
|
| |received | | |
|
|
| | | | |
|
|
+<-----+ | | |
|
|
| | | |
|
|
+------------------------------>+ | |
|
|
|decode_pldm_cmd(pldm_response) | | |
|
|
| | | |
|
|
+------------------------------>+ | |
|
|
|close_connection() | | |
|
|
+ + + +
|
|
```
|
|
|
|
##### Alternative to the proposed requester design
|
|
|
|
a) Define D-Bus interfaces to send and receive PLDM messages :
|
|
|
|
```
|
|
method sendPLDM(uint8 mctp_eid, uint8 msg[])
|
|
|
|
signal recvPLDM(uint8 mctp_eid, uint8 pldm_instance_id, uint8 msg[])
|
|
```
|
|
|
|
PLDM requester apps can then invoke the above applications. While this
|
|
simplifies things for the user, it has two disadvantages :
|
|
|
|
- the app implementing such an interface could be a single point of failure,
|
|
plus sending messages concurrently would be a challenge.
|
|
- the message payload could be large (several pages), and copying the same for
|
|
D-Bus transfers might be undesirable.
|
|
|
|
### Multiple transport channels
|
|
|
|
The PLDM daemon might have to talk to remote PLDM devices via different
|
|
channels. While a level of abstraction might be provided by MCTP, the PLDM
|
|
daemon would have to implement a D-Bus interface to target a specific transport
|
|
channel, so that requester apps on the BMC can send messages over that
|
|
transport. Also, it should be possible to plug-in platform specific D-Bus
|
|
objects that implement an interface to target a platform specific transport.
|
|
|
|
### Processing PLDM FRU information sent down by the host firmware
|
|
|
|
Note: while this is specific to the host BMC communication, most of this might
|
|
apply to processing PLDM FRU information received from a device connected to the
|
|
BMC as well.
|
|
|
|
The requirement is for the BMC to consume PLDM FRU information received from the
|
|
host firmware and then have the same exposed via Redfish. An example can be the
|
|
host firmware sending down processor and core information via PLDM FRU commands,
|
|
and the BMC making this information available via the Processor and
|
|
ProcessorCollection schemas.
|
|
|
|
This design is built around the pldmd and entity-manager applications on the
|
|
BMC:
|
|
|
|
- The pldmd asks the host firmware's PLDM stack for the host's FRU record table,
|
|
by sending it the PLDM GetFRURecordTable command. The pldmd should send this
|
|
command if the host indicates support for the PLDM FRU spec. The pldmd
|
|
receives a PLDM FRU record table from the host firmware (
|
|
www.dmtf.org/sites/default/files/standards/documents/DSP0257_1.0.0.pdf). The
|
|
daemon parses the FRU record table and hosts raw PLDM FRU information on
|
|
D-Bus. It will house the PLDM FRU properties for a certain FRU under an
|
|
xyz.openbmc_project.Inventory.Source.PLDM.FRU D-Bus interface, and house the
|
|
PLDM entity info extracted from the FRU record set PDR under an
|
|
xyz.openbmc_project.Source.PLDM.Entity interface.
|
|
|
|
- Configurations can be written for entity-manager to probe an interface like
|
|
xyz.openbmc_project.Inventory.Source.PLDM.FRU, and create FRU inventory D-Bus
|
|
objects. Inventory interfaces from the xyz.openbmc_project. Inventory
|
|
namespace can be applied on these objects, by converting PLDM FRU property
|
|
values into xyz.openbmc_project.Invnetory.Decorator.Asset property values,
|
|
such as Part Number and Serial Number, in the entity manager configuration
|
|
file. Bmcweb can find these FRU inventory objects based on D-Bus interfaces,
|
|
as it does today.
|
|
|
|
## Alternatives Considered
|
|
|
|
Continue using IPMI, but start making more use of OEM extensions to suit the
|
|
requirements of new platforms. However, given that the IPMI standard is no
|
|
longer under active development, we would likely end up with a large amount of
|
|
platform-specific customisations. This also does not solve the hardware channel
|
|
issues in a standard manner. On OpenPOWER hardware at least, we've started to
|
|
hit some of the limitations of IPMI (for example, we have need for >255
|
|
sensors).
|
|
|
|
## Impacts
|
|
|
|
Development would be required to implement the PLDM protocol, the
|
|
request/response model, and platform specific handling. Low level design is
|
|
required to implement the protocol specifics of each of the PLDM Types. Such low
|
|
level design is not included in this proposal.
|
|
|
|
Design and development needs to involve the firmware stacks of management
|
|
controllers and management devices of a platform management subsystem.
|
|
|
|
## Testing
|
|
|
|
Testing can be done without having to depend on the underlying transport layer.
|
|
|
|
The responder function can be tested by mocking a requester and the transport
|
|
layer: this would essentially test the protocol handling and platform specific
|
|
handling. The requester function can be tested by mocking a responder: this
|
|
would test the instance id handling and the send/receive functions.
|
|
|
|
APIs from the shared libraries can be tested via fuzzing.
|