# OpenBMC State Management and External Interfaces
|
||
|
||
Author: Andrew Geissler (geissonator)
|
||
|
||
Other contributors: Jason Bills (jmbills)
|
||
|
||
Created: Jan 22, 2020
|
||
|
||
## Problem Description
|
||
|
||
As OpenBMC moves to fully supporting the Redfish protocol, it's important to
|
||
have the appropriate support within OpenBMC for the [ResetType][1] within the
|
||
Resource schema. OpenBMC currently has limited support and the goal with this
|
||
design is to get that support more complete.
|
||
|
||
Please note that the focus of this document is on the following `ResetType`
|
||
instance: `redfish/v1/Systems/system/Actions/ComputerSystem.Reset`
|
||
|
||
This support will also map to the existing IPMI Chassis Control command.
|
||
|
||
## Background and References
|
||
|
||
[phoshor-state-manager][2] implements the xyz.openbmc_project.State.\*
|
||
interfaces. These interfaces control and track the state of the BMC, Chassis,
|
||
and Host within an OpenBMC managed system. The README within the repository can
|
||
provide some further background information. [bmcweb][3], OpenBMC's web server
|
||
and front end Redfish interface, then maps commands to the ResetType object to
|
||
the appropriate xyz.openbmc_project.State.\* D-Bus interface.
|
||
|
||
The goal with this design is to enhance the xyz.openbmc_project.State.\*
|
||
interfaces to support more of the Redfish ResetType. Specifically this design is
|
||
looking to support the capability to reboot an operating system on a system
|
||
without cycling power to the chassis.
|
||
|
||
Currently phosphor-state-manager supports the following:
|
||
|
||
- Chassis: On/Off
|
||
- Host: On/Off/Reboot
|
||
|
||
The `Reboot` to the host currently causes a power cycle to the chassis.
|
||
|
||
### Redfish
|
||
|
||
The Redfish [ResetType][1] has the following operations associated with it:
|
||
|
||
```
|
||
"ResetType": {
|
||
"enum": [
|
||
"On",
|
||
"ForceOff",
|
||
"GracefulShutdown",
|
||
"GracefulRestart",
|
||
"ForceRestart",
|
||
"Nmi",
|
||
"ForceOn",
|
||
"PushPowerButton",
|
||
"PowerCycle"
|
||
],
|
||
"enumDescriptions": {
|
||
"ForceOff": "Turn off the unit immediately (non-graceful shutdown).",
|
||
"ForceOn": "Turn on the unit immediately.",
|
||
"ForceRestart": "Shut down immediately and non-gracefully and restart
|
||
the system.",
|
||
"GracefulRestart": "Shut down gracefully and restart the system.",
|
||
"GracefulShutdown": "Shut down gracefully and power off.",
|
||
"Nmi": "Generate a diagnostic interrupt, which is usually an NMI on x86
|
||
systems, to stop normal operations, complete diagnostic actions, and,
|
||
typically, halt the system.",
|
||
"On": "Turn on the unit.",
|
||
"PowerCycle": "Power cycle the unit.",
|
||
"PushPowerButton": "Simulate the pressing of the physical power button
|
||
on this unit."
|
||
},
|
||
"type": "string"
|
||
},
|
||
```
|
||
|
||
### IPMI
|
||
|
||
The IPMI specification defines a Chassis Control Command with a chassis control
|
||
parameter as follows:
|
||
|
||
| Option | Description |
|
||
| ------------------------------ | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
||
| power down | Force system into soft off (S4/S45) state. This is for ‘emergency’ management power down actions. The command does not initiate a clean shut-down of the operating system prior to powering down the system. |
|
||
| power up | |
|
||
| power cycle | This command provides a power off interval of at least 1 second following the deassertion of the system’s POWERGOOD status from the main power subsystem. It is recommended that no action occur if system power is off (S4/S5) when this action is selected, and that a D5h “Request parameter(s) not supported in present state.” error completion code be returned. |
|
||
| hard reset | In some implementations, the BMC may not know whether a reset will cause any particular effect and will pulse the system reset signal regardless of power state. |
|
||
| pulse Diagnostic Interrupt | Pulse a version of a diagnostic interrupt that goes directly to the processor(s). This is typically used to cause the operating system to do a diagnostic dump (OS dependent). |
|
||
| Initiate a soft-shutdown of OS | |
|
||
|
||
## Requirements
|
||
|
||
- Keep legacy support where `xyz.openbmc_project.State.Host.Transition.Reboot`
|
||
causes a graceful shutdown of the host, a power cycle of the chassis, and a
|
||
starting of the host.
|
||
- Support a reboot of the host with chassis power on
|
||
- Support `GracefulRestart` (where the host is notified of the reboot)
|
||
- Support `ForceRestart` (where the host is not notified of the reboot)
|
||
- Map `PowerCycle` to a host or chassis operation depending on the current state
|
||
of the system.
|
||
- If host is running, then a `PowerCycle` should cycle power to the chassis
|
||
and boot the host.
|
||
- If host is not running, then a `PowerCycle` should only cycle power to the
|
||
chassis.
|
||
|
||
## Proposed Design
|
||
|
||
Create two new `xyz.openbmc_project.State.Host.Transition` options:
|
||
|
||
- `ForceWarmReboot`, `GracefulWarmReboot`
|
||
|
||
Create a new `xyz.openbmc_project.State.Chassis.Transition` option:
|
||
|
||
- `PowerCycle`
|
||
|
||
The existing bmcweb code uses some additional xyz.openbmc_project.State.\*
|
||
interfaces that are not defined within phosphor-dbus-interfaces. These are
|
||
implemented within the x86-power-control repository which is an alternate
|
||
implementation to phosphor-state-manager. It has the following mapping for these
|
||
non-phosphor-dbus-interfaces
|
||
|
||
- `ForceRestart` -> `xyz.openbmc_project.State.Chassis.Transition.Reset`
|
||
- `PowerCycle` -> `xyz.openbmc_project.State.Chassis.Transition.PowerCycle`
|
||
|
||
A `ForceRestart` should restart the host, not the chassis. The proposal is to
|
||
change the current bmcweb mapping for `ForceRestart` to a new host transition:
|
||
`xyz.openbmc_project.State.Host.Transition.ForceWarmReboot`
|
||
|
||
A `GracefulRestart` will map to our new host transition:
|
||
`xyz.openbmc_project.State.Host.Transition.GracefulWarmReboot`
|
||
|
||
The `PowerCycle` operation is dependent on the current state of the host. If
|
||
host is on, it will map to `xyz.openbmc_project.State.Host.Transition.Reboot`
|
||
otherwise it will map to
|
||
`xyz.openbmc_project.State.Chassis.Transition.PowerCycle`
|
||
|
||
To summarize the new Redfish to xyz.openbmc_project.State.\* mappings:
|
||
|
||
- `ForceRestart` -> `xyz.openbmc_project.State.Host.Transition.ForceWarmReboot`
|
||
- `GracefulRestart`->
|
||
`xyz.openbmc_project.State.Host.Transition.GracefulWarmReboot`
|
||
- `PowerCycle`:
|
||
- If host on: `xyz.openbmc_project.State.Host.Transition.Reboot`
|
||
- If host off: `xyz.openbmc_project.State.Chassis.Transition.PowerCycle`
|
||
|
||
The full mapping of Redfish and IPMI to xyz.openbmc_project.State.\* is as
|
||
follows:
|
||
|
||
| Redfish | IPMI | xyz.openbmc_project.State.Transition |
|
||
| --------------------- | ----------- | ------------------------------------ |
|
||
| ForceOff | power down | Chassis.Off |
|
||
| ForceOn | power up | Host.On |
|
||
| ForceRestart | hard reset | Host.ForceWarmReboot |
|
||
| GracefulRestart | | Host.GracefulWarmReboot |
|
||
| GracefulShutdown | soft off | Host.Off |
|
||
| On | power up | Host.On |
|
||
| PowerCycle (host on) | power cycle | Host.Reboot |
|
||
| PowerCycle (host off) | | Chassis.PowerCycle |
|
||
|
||
## Alternatives Considered
|
||
|
||
No other alternatives considered.
|
||
|
||
## Impacts
|
||
|
||
Existing interfaces will be kept the same. Some changes in x86-power-control
|
||
would be needed to ensure the bmcweb mappings work as expected with the new
|
||
interfaces.
|
||
|
||
Some changes in phosphor-host-ipmid would be needed to support the new state
|
||
transitions.
|
||
|
||
## Testing
|
||
|
||
These new state transitions will be backed by systemd targets. These targets
|
||
will be thoroughly tested. OpenBMC test team will be approached to ensure these
|
||
are tested in automation.
|
||
|
||
[1]: http://redfish.dmtf.org/schemas/v1/Resource.json#/definitions/ResetType
|
||
[2]: https://github.com/openbmc/phosphor-state-manager
|
||
[3]: https://github.com/openbmc/bmcweb
|
||
[4]: https://gerrit.openbmc.org/c/openbmc/docs/+/22358
|