# IPMITOOL-cheatsheet.md
This document is intended to provide a set of ipmitool commands for OpenBMC
usage.
## Power
#### 1. View server status
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power status
```
#### 2. Server power on
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power on
```
#### 3. Server power off
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power off
```
#### 4. Server power reset
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power reset
```
#### 5. Server power cycle
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power cycle
```
#### 6. Server power soft
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power soft
```
#### 7. Send a diagnostic interrupt directly to the processor(not support)
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" power diag
```
## Users
#### 1. View information for all users
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user list
```
#### 2. Display a brief summary of BMC users
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user summary
```
#### 3. Create a BMC user with a given name
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user set name <userid> <username>
```
#### 4. Set a given user with a given password
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user set password <userid>[<password>]
```
#### 5. Disable designated users from accessing BMC
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user disable <userid>
```
#### 6. Enable the specified user to access BMC
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" user enable <userid>
```
## Field-replaceable Unit (FRU)
#### 1. View FRU information
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" fru list
```
## Sensor Data Record (SDR)
#### 1. View SDR information
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sdr
```
#### 2. Query related SDR information in BMC
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sdr info
```
#### 3. View sensor date records
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sdr list [all|full|compact|event|mcloc|fru|generic]
##
all : All SDR records (sensors and positioners)
full : Complete sensor recording
compact : Simple sensor recording
event : Event information recorded by the sensor
mcloc : Manage controller locator records
fru : FRU (Field Replaceable Unit) locator record
generic : General SDR records
```
## Sensors
#### 1. View sensor information
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sensor list
```
## Management Controller (MC)
#### 1. Instruct the BMC to perform a cold reset
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" mc reset cold
```
#### 2. Instruct the BMC to perform a warm reset(not supported)
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" mc reset warm
```
#### 3. View BMC information
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" mc info
```
#### 4. View the currently available operation options of BMC
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" mc getenables
```
## Channels
#### 1. Display the authentication function about the selected information
#### channel
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" channel authcap <channel number> <max privilege>
```
#### 2. Display the information for the selected channel
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" channel info [<channel number>]
```
#### 3. View channel information
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" channel info
```
## Chassis
#### 1. Display information about the high-level status of the system rack and
#### power subsystem.
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis status
```
#### 2. The command will return the power on time
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis poh
```
#### 3. Query the reason for the last system restart.(not supported)
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis restart_cause
```
#### 4. Set rack power strategy in case of power failure
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis policy <state>
##
list : return supported policies
always-on : turn on when power is restored
previous : return to previous state when power is restored
always-off : stay off after power is restored
```
#### 5. View and change power status
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis power
##
status : show current status
on : power on
off : power off
reset : power reset
soft : power soft
cycle : power cycle
```
#### 6. Set boot device for next system restart
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootdev <device>
```
##
Currently supported devices:
| device | function |
| :----: | ----------------------------------------------------------- |
| none | do not change boot device |
| pxe | boot from pxe |
| disk | boot from BIOS default boot device |
| safe | boot from BIOS default boot device,but requires a safe mode |
| diag | boot from the diagnostic partition |
| cdrom | boot from the CD/DVD |
| bios | enter bios settings |
##
If you want to make your override persistent over reboots use the `persistent`
option:
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootdev <device> options=persistent
```
##
If the main host machine is based on the x86 CPU you need also pay attention to
the legacy/EFI mode selector. By default IPMI overrides boot source with the
legacy mode enabled. To set EFI mode use `efiboot` option:
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootdev <device> options=efiboot
```
You can combine options with a help of `,`:
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootdev <device> options=persistent,efiboot
```
##
To read current boot source override setting:
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis bootparam get 5
```
#### 7. Control panel logo light
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" chassis identify <interval>
```
## Local Area Network(LAN)
#### 1. Output the current configuration information of a given channel
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" lan print [<channel number>]
```
#### 2. Set the given parameters for the given channel
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" lan set <channel> <command> <parameter>
##
Valid parameter
ipaddr <x.x.x.x> : Set ip for this channel
netmask <x.x.x.x> : Set netmask for this channel
macaddr<xx:xx:xx:xx:xx:xx> : Set the mac address for this channel
defgw ipaddr <x.x.x.x> : Set the default gateway IP address
defgw macaddr<xx:xx:xx:xx:xx:xx> : Set the mac address of the default gateway
bakgw ipaddr <x.x.x.x> : Set the IP address of the backup gateway
bakgw macaddr<xx:xx:xx:xx:xx:xx> : Set the IP address of the backup gateway
password <pass> : Set no user password
access <on|off> : Set the LAN channel access mode
```
## System Event Log (SEL)
#### 1. Query the relevant information about SEL and its content in BMC
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sel info
```
#### 2. Clear the information in SEL,but it cannot be undone.
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sel clear
```
#### 3. Delete a single event
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sel delete <number>
```
#### 4. Display the current time of the SEL clock
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sel time get
```
## Session
#### 1. Display session information
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" session info all
```
## Serial Over Lan (SOL)
#### 1. Retrieve Serial-Over-LAN configuration information for the specified
#### channel.
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sol info [<channel number>]
```
#### 2. Put ipmitool into Serial Over LAN mode
```
$ ipmitool -C 17 -H "$BMC_IP" -I lanplus -U "$BMC_USER" -P "$BMC_PASSWD" sol activate
```
#### 3. Disable serial LAN in BMC mode
```