# VPD collection app on OpenBMC
|
|
|
|
Author: Santosh Puranik <santosh.puranik@in.ibm.com> <santosh.puranik>
|
|
|
|
Created: 2019-06-11
|
|
|
|
## Problem Description
|
|
|
|
On OpenBMC, Vital Product Data (VPD) collection is limited to only one or two
|
|
Field Replaceable Units (FRUs) today - one example is the BMC FRU. On OpenPower
|
|
systems, the BMC also supports just one VPD format, the [OpenPower VPD] [1] format.
|
|
As a part of its enterprise class servers, IBM will use the IPZ format VPD, which
|
|
the BMC currently does not support. Certain FRUs also have keyword format VPD.
|
|
|
|
The BMC requires to read VPD for all FRUs for several reasons:
|
|
|
|
- Some of the VPD information such as FRU part number, serial number need to be
|
|
included in the Platform Error Logs (PELs) for calling out FRUs for service.
|
|
|
|
- Several use cases on the BMC require that the applications decide on a certain
|
|
code path based on what level of FRU is plugged in. For example, the
|
|
application that controls voltage regulators might need to set different
|
|
registers based on the version of the voltage regulator FRU.
|
|
|
|
- There are use cases for the BMC to send VPD data to the host
|
|
hypervisor/operating system (over PLDM). This is mainly so that the host can
|
|
get VPD that is not directly accessible to it.
|
|
|
|
The VPD data itself may reside on an EEPROM (typical) or may be synthesized out
|
|
of certain parameters of the FRU (atypical - for FRUs that do not have an
|
|
EEPROM).
|
|
|
|
This design document aims to define a high level design for VPD collection and
|
|
VPD access on OpenBMC. It does _not_ cover low level API details.
|
|
|
|
## Background and References
|
|
|
|
Essentially, the IPZ VPD structure consists of key-value pairs called keywords.
|
|
Each keyword can be used to contain specific data about the FRU. For example,
|
|
the SN keyword will contain a serial number that can uniquely identify an
|
|
instance of a part. Keywords themselves can be combined or grouped into records.
|
|
For example, a single record can be used to group keywords that have similar
|
|
function, such as serial number, part number.
|
|
|
|
The keyword format VPD does not contain records, but instead has just keywords
|
|
laid out one after another.
|
|
|
|
The IPZ format is quite similar in its structure to the OpenPower format except
|
|
for the following details:
|
|
|
|
- IPZ VPD has different records and keywords.
|
|
|
|
- IPZ VPD is required to implement and validate ECC as defined in the OpenPower
|
|
specification. The BMC code currently does not validate/use ECC although the
|
|
specification does define it, but will need to use the ECC for IBM's
|
|
enterprise class of servers.
|
|
|
|
- The keyword format VPD is also something that consists of key-value pairs, but
|
|
has no concept of a record to group keywords together. The ECC for the keyword
|
|
format VPD is simply a CRC.
|
|
|
|
## Requirements
|
|
|
|
The following are requirements for the VPD function on OpenBMC:
|
|
|
|
- The BMC must collect VPD for all FRUs that it has direct access to by the time
|
|
the BMC reaches Standby (aka the Ready state, a state from where the BMC can
|
|
begin CEC poweron). This is needed for several reasons:
|
|
|
|
BMC applications need to be able to read VPD for FRUs to determine, for ex.,
|
|
the hardware level of the FRU.
|
|
|
|
Some of the VPD will need to be exchanged with the host.
|
|
|
|
Manufacturing and Service engineers need the ability to view and program the
|
|
FRU VPD without powering the system ON.
|
|
|
|
Certain system level VPD is also used by applications on the BMC to determine
|
|
the system type, model on which it is running.
|
|
|
|
- If a FRU does not have a VPD store such as an EEPROM, the BMC should be able
|
|
to synthesize VPD for such FRUs. Details on VPD synthesis will be in its own
|
|
design document and are not covered here.
|
|
|
|
- The BMC should be able to recollect VPD for FRUs that can be hotplugged or
|
|
serviced when the BMC is running.
|
|
|
|
- The BMC must log errors if any of the VPD cannot be properly parsed or fails
|
|
ECC checks.
|
|
|
|
- The BMC must create/update FRU inventory objects for all FRUs that it collects
|
|
VPD for. The inventory D-Bus object must contain (among other details), the
|
|
serial number, part number and CCIN (an IBM way of differentiating different
|
|
versions of a FRU) of the FRU.
|
|
|
|
- Applications on the BMC need to have the ability to query any given VPD
|
|
keyword for a given FRU.
|
|
|
|
- Applications also need to have the ability to update the VPD contents in a
|
|
FRU. For example, the BMC needs to have the ability to update the system VPD
|
|
in scenarios where the FRU containing the system VPD is repaired in the field.
|
|
|
|
- There needs to be a tool/API that allows viewing and updating VPD for any
|
|
given FRU. This includes FRUs that the BMC does not directly collect VPD for
|
|
(such as FRUs that can be accessed both by the BMC and the host, but the host
|
|
collects VPD for)
|
|
|
|
## Proposed Design
|
|
|
|
This document covers the architectural, interface, and design details. It
|
|
provides recommendations for implementations, but implementation details are
|
|
outside the scope of this document.
|
|
|
|
The proposal here is to build upon the existing VPD collection design used by
|
|
open power. The current implementation consists of the following entities:
|
|
|
|
- [op-vpd-parser] [2] service, which parses the contents of an EEPROM containing
|
|
VPD in the OpenPower VPD format.
|
|
|
|
- A udev [rule] [3] that is used by systemd to launch the above service as
|
|
EEPROM devices are connected.
|
|
|
|
- A set of config [files] [4] that describe the inventory objects and D-Bus
|
|
properties to update for a given FRU.
|
|
|
|
In order to meet the requirements noted in the previous section, the following
|
|
updates will be made:
|
|
|
|
- Two new services will be created to handle the new VPD formats. ipz-vpd-parser
|
|
and a keyword-vpd-parser. These services shall be templated to allow for
|
|
multiple instances to be run.
|
|
|
|
- Another service will be created to update the inventory with location code
|
|
information. Since the location code expansion comes from the system VPD, this
|
|
service can only be launched after the system VPD (stored on the backplane) is
|
|
collected.
|
|
|
|
- There will be one udev rule per EEPROM on the system from which the BMC has to
|
|
collect VPD. We could also have just a single rule, but that would mean we
|
|
would have to filter out non-VPD EEPROMs somehow.
|
|
|
|
- Each udev rule will be setup to launch an instance of one of the VPD parser
|
|
services (The format of the VPD in any given EEPROM are known at build time as
|
|
they are system specific)
|
|
|
|
- The service (one instance of ipz-vpd-parser or keyword-vpd-parser), when
|
|
launched, will read the EEPROM, parse its contents and use config files to
|
|
determine what VPD contents to store in the inventory.
|
|
|
|
- The service will update the inventory D-Bus object with the contents of the
|
|
VPD in the following format: There will be one interface per record (ex, VINI
|
|
record) which will have each keyword as a property (ex, FN, PN). This will
|
|
allow us to support multiple records that can have the same keyword and will
|
|
also serve as means to logically group keywords in the inventory, quite
|
|
similar to how they are grouped in the actual VPD. For example (some names
|
|
here are made up, but they help illustrate the point), for the VINI record
|
|
containing keywords SN, FN and CCIN, the representation in D-Bus would look
|
|
like:
|
|
|
|
```
|
|
Interface: com.ibm.ipzvpd.VINI
|
|
Properties:
|
|
SN
|
|
FN
|
|
CCIN
|
|
```
|
|
|
|
- In case of keyword format VPD, all keywords shall be placed as properties
|
|
under a single interface.
|
|
|
|
- The parser services will not format or transform the data in VPD in any way
|
|
before updating the properties noted above, the properties shall be stored as
|
|
byte arrays. Note, however, that the services will continue updating the
|
|
commonly used FRU properties such as SerialNumber, PartNumber as strings, just
|
|
as the openpower-vpd-parser does.
|
|
|
|
- To handle VPD writes, another systemd service will be launched once all the
|
|
VPD read services have completed. This service shall be a daemon that will
|
|
manage parallel writes to EEPROMs. The VPD writer service will expose D-bus
|
|
interfaces to update VPD for a FRU given its inventory path.
|
|
|
|
- Generation of the udev rules and configs shall be layered such that they can
|
|
be tweaked on a per-system basis.
|
|
|
|
### Open topics
|
|
|
|
Some open questions:
|
|
|
|
- Some more thought is needed on how concurrent maintenance (replacing a FRU
|
|
when the host is up and running) will be handled. That will be presented in
|
|
its own design document.
|
|
|
|
## Alternatives Considered
|
|
|
|
The following alternative designs were considered:
|
|
|
|
### Write a standalone VPD server app
|
|
|
|
One option considered was to develop a standalone, do-it-all VPD application on
|
|
the BMC that collects all of the VPD by BMC standby. The application has to be a
|
|
daemon that will expose a set of D-bus interfaces to:
|
|
|
|
- Collect/recollect all VPD.
|
|
- Query a given FRU for its VPD. Example read the serial number of the VRM.
|
|
- Update the VPD keyword(s) for a given FRU.
|
|
- Concurrently maintain a FRU, which will in turn perform a remove/add/replace
|
|
operation.
|
|
|
|
The application would be driven off of a configuration file that lists the FRUs
|
|
available for a given system, their I2C bus address, slave address etc.
|
|
|
|
This option was rejected for the following reasons:
|
|
|
|
- Design would make the application very specific to a given system or a set of
|
|
VPD formats. Although the application could be written in a way that allows
|
|
plugging in support for different VPD formats, it was deemed that the current
|
|
approach of small applications that target a very specific requirement is
|
|
better.
|
|
- The design does not leverage upon the layered design approach that the chosen
|
|
option allows us to do.
|
|
|
|
### Build upon the entity manager
|
|
|
|
Using the entity manager: https://github.com/openbmc/entity-manager. The Entity
|
|
manager has an application called the FruDevice, which probes /dev/i2c/ for
|
|
EEPROMs, reads (IPMI format) VPD and stores it on DBUS.
|
|
|
|
The application could be enhanced to:
|
|
|
|
- Add support for other VPD formats such as the IPZ and keyword format.
|
|
- Perhaps update a different set of data into a different DBUS object, like the
|
|
Inventory manager.
|
|
- Change the external DBUS interfaces that read/write FRU data to take an
|
|
inventory path (instead of the I2C path, address it takes in today).
|
|
|
|
This option was rejected for the following reasons:
|
|
|
|
- We do not need the full spectrum of functions offered by the entity manager,
|
|
that is we do not want to replace the existing inventory manager. Moving away
|
|
from the inventory manager for Power systems is outside of the scope of this
|
|
document.
|
|
- The code did not appear very pluggable to add support for new VPD formats, we
|
|
might have to end up just utilizing #ifdef's to separate functions.
|
|
- Does not have a way to determine system blueprint for FRU devices, scans the
|
|
entire /dev/ tree to pick out EEPROMs.
|
|
|
|
## Impacts
|
|
|
|
The following impacts have been identified:
|
|
|
|
- The services to parse VPD and store it in the inventory will add some time to
|
|
the BMC boot flow. The impact should be kept to a minimum by achieving maximum
|
|
possible parallelism in the launching of these services.
|
|
- Applications that need to read VPD keywords will be impacted in the sense that
|
|
they would have to use the inventory interfaces to fetch the data they are
|
|
interested in.
|
|
|
|
## Testing
|
|
|
|
VPD parsing function can be tested by faking out the VPD EEPROMs as files on the
|
|
filesystem. Such testing can also ensure that the right set of VPD data makes
|
|
its way into the OpenBMC Inventory. There is also a proposal to build in a file
|
|
mode into the application. The file mode will not need real hardware to test the
|
|
code functions, but can use files on the BMC to mimic the EEPROMs.
|
|
|
|
VPD writes can be tested by writing a small command line utility that can invoke
|
|
the VPD write application's APIs to write VPD.
|
|
|
|
[1]:
|
|
https://www-355.ibm.com/systems/power/openpower/posting.xhtml?postingId=1D060729AC96891885257E1B0053BC95
|
|
[2]:
|
|
https://github.com/openbmc/meta-openpower/blob/master/recipes-phosphor/vpd/openpower-fru-vpd/op-vpd-parser.service
|
|
[3]:
|
|
https://github.com/openbmc/meta-openpower/blob/master/recipes-phosphor/vpd/openpower-fru-vpd/70-op-vpd.rules
|
|
[4]:
|
|
https://github.com/openbmc/meta-openpower/blob/master/recipes-phosphor/vpd/openpower-fru-vpd-layout/layout.yaml
|